PNI Sensor Corporation DOC#1014688 r06
TCM User Manual – July 2013 Page 8
4 Set-Up
This section describes how to configure the TCM in your host system. To install the TCM into
your system, follow these steps:
Make electrical connections to the TCM.
Evaluate the TCM using TCM Studio or a binary terminal emulation program, such as
RealTerm or Tera Term, to ensure the compass generally works correctly.
Choose a mounting location.
Mechanically mount the TCM in the host system.
Perform a user calibration.
4.1 Electrical Connections
The TCM XB incorporates a 9 pin Molex connector, part number 53780-0970, which mates
with Molex part 51146-0900 or equivalent. The TCM MB incorporates a 4 pin Mil-Max
connector, part number 850-10-004-10-001000, which mates with Mill-Max part 851-XX-
004-10-001000 or equivalent. The pin-out is given below in Table 4-1.
Table 4-1: TCM Pin Descriptions
Footnote:
1. For the TCM XB, pin #1 is indicated on Figure 3-1, while for the TCM MB, pin
#1 is the pin closest to the corner.
After making the electrical connections, it is a good idea to perform some simple tests to
ensure the TCM is working as expected. See Section 5 for how to operate the TCM with
TCM Studio, or Section 7 for how to operate the TCM using the PNI binary protocol.