TCM User Manual July 2013 Page 5
Table 3-4: I/O Characteristics
Parameter
Value
Communication
Interface
TCM XB
RS232 UART
TCM MB
CMOS/TTL UART
Communication Protocol
PNI Binary
Communication Rate
300 to 115200 baud
Maximum Sample Rate
1
~30 samples/sec
Time to Initial
Good Data
2
Initial power up
<210 ms
Sleep Mode recovery
<80 ms
Footnotes:
1. The maximum sample rate is dependent on the strength of the magnetic
field, and typically will be from 25 to 32 samples/sec.
2. FIR taps set to “0”.
Table 3-5: Environmental Requirements
Parameter
Value
Operating Temperature
1
-40C to +85C
Storage Temperature
-40C to +85C
Footnote:
1. To meet performance specifications across this range,
recalibration will be necessary as the temperature varies.
Table 3-6: Mechanical Characteristics
Parameter
Value
Dimensions
(l x w x h)
TCM XB
35 x 43 x 13 mm
TCM MB
33 x 31 x 13 mm
Weight
TCM XB
6.8 gm
TCM MB
5.3 gm
Connector
TCM XB
9-pin Molex, pn 53780-0970
TCM MB
4-pin MIL-MAX, pn 850-10-004-10-001000